Add preset resolution configuration and log file name parameters to launch parameters documentation

This commit is contained in:
ob-yalian
2025-12-30 13:57:11 +08:00
parent 2e78c8292b
commit 61c3d722d0
2 changed files with 10 additions and 2 deletions
@@ -43,6 +43,8 @@ The following are the launch parameters available:
* Enable Right IR image transport plugins. Default: `["image_transport/compressed", "image_transport/raw", "image_transport/theora"]`.
* **`point_cloud_decimation_filter_factor`**
* Point cloud downsampling factor. Range: `1–8`. `1` means no downsampling; larger values apply stronger decimation.
* **`preset_resolution_config`**
* Preset resolution configuration for the camera device. Format: "width,height,ir_decimation_factor,depth_decimation_factor". Example: "1280,720,4,4". Only supported on specific devices like Gemini2. Leave empty to disable.
### Sensor Controls
@@ -183,7 +185,7 @@ The following are the launch parameters available:
* `COLOR`: Align depth to color.
* `DEPTH`: Align color to depth.
- **`intra_camera_sync_reference`**
- Sets the reference point for intra-camera synchronization. Applicable for Gemini 330 series devices when `sync_mode` is set to **software** or **hardware trigger** mode. **Options:** `Start`, `Middle`, `End`. **Default:** `Middle`
- Sets the reference point for intra-camera synchronization. Applicable for Gemini 330 series devices when `sync_mode` is set to **software** or **hardware trigger** mode. **Options:** `Start`, `Middle`, `End`. When set to empty, the long baseline device defaults to End, and the short baseline device defaults to Middle.
### Basic & General Parameters
@@ -226,6 +228,8 @@ The following are the launch parameters available:
#### Logging & Diagnostics
* **`log_level`**
* SDK log level. Default is `info`. Optional values: `debug`, `info`, `warn`, `error`, `fatal`.
* **`log_file_name`**
* Saved SDK log file name. Effective when `log_level` is `debug`.
* **`diagnostic_period`**
* Diagnostic period in seconds.
* **`enable_heartbeat`**